Products Description

The Next Generation Distribution System

To protect against electrical hazards, conventional commercial and industrial distribution systems usually incorporated with basic short circuit and overload protections only. When additional protection devices are required, the system becomes bulky and costly.

Back by extensive R&D, we have created a revolutionary distribution system. By utilizing the electronic control circuit in the "Central Monitor Unit ", our Distribution Board is able to detect and protect against the following abnormal conditions in a compact and affordable manner:

  • Earth leakage
  • Short Circuit
  • Over-load
  • Over-voltage
  • Phase failure
  • Phase voltage unbalance
  • Surge

Our three phase Distribution Board provides complete safety protection coverage for commercial and industrial users. A single phase distribution board is also available to provide protection for your home.

The New Generation 3-Phase 4-Wire Distribution System


3 phase

6 Functions 3 Phase MCB

  • Earth Leakage Protection
  • Over Current Protection
  • Phase Failure Protection
  • Phase Voltage Unbalance Protection
  • Short Circuit Protection
  • Surge Protection

Specifications

Supply voltage: 3-4 Pole 220
380 VAC 50/50 Hz
Rated Over-current: 8A - 20A (adjustable)
Over Current tripping time: < 1 second
Earth Leakage Sensitivity: 3.5 mA +/- 0.5 mA
Unbalance Voltage Tripping Time: < 2 seconds
Unbalance voltage tripping rate:
+/- 30%
Short Circuit Breaking Capacity:
10KA
Note 1.
Main Switch Rated Current
125A
Breaking capacity: 15KA
Note 2.
Earth leakage protection conforms with USA UL943 Class A safety standard.

The New Generation Single-Phase 220 VAC Distribution System


Single phase 220

5 Functions Single Phase MCB

  • Earth Leakage Protection
  • Over Current Protection
  • Over Voltage Protection
  • Short Circuit Protection
  • Surge Protection

Specifications

color="#FFFFFF">Note 2.
Supply voltage: 2 Pole
220VAC 50/60Hz
Rated over-current: 8A - 20A (adjustable)
Over current tripping time: < 1 second
Earth leakage sensitivity:
3.5mA +/- 0.5mA
Earth leakage tripping time
< 40ms
Over voltage tripping rate: 265V +/- 5%
Short circuit breaking capacity 6KA
Note 1.
Main switch rated current: 63A
Breaking capacity: 10KA
Note 2.
Earth leakage protection conforms with USA UL943 Class A standard.

The Next Generation Circuit Breaker

Implemented with advance techonology, the following types of circuit breaker have been developed to suit different applications: be that domestic, commercial and industrial applications.

Smart Control Power Switch TP-81

This is a two to three phase, 6 functions in 1 on/off switch. It incorporated with overload, short circuit, earth leakage (ground fault), phase failure, phase voltage unbalance and surge protections for industrial application. Ideal for machineries and equipments.

TP-81

Specifications
Rated voltage: 220/380 VAC
50/60 Hz, 2-4 pole
Rated current: 15/30 A
Overload tripping time: < 2 seconds
Short circuit tripping time: < 40 ms
Phase failure & unbalance voltage tripping time: < 2 seconds
Unbalance voltage tripping rate:
+/- 25%
Earth leakage sensitivity:
3 mA +/-0.5mA
Earth leakage tripping time:
< 40 ms
Breaking capacity: 1KA (380V)
Size: 80 x 44 x 66 mm


Smart Control Power Switch SP-42

This is a single phase, 5 functions in 1 circuit breaker designed for commercial and domestic use. It incorporated overload, short circuit, earth leakage (ground fault), over voltage and surge protections. It provides the best safety protection against electrical hazards, hence it is ideal for use in homes, hospitals and hotel rooms.

SP-42 Specifications
Rated voltage: 110V/220V AC
50/60 Hz, 2 pole
Rated current: 15/30 A
Overload tripping time: < 1 second
Earth leakage sensitivity:
3 mA +/-0.5mA
Earth leakage tripping time:
< 40 ms
Over voltage tripping rate: > rated voltage 15%
Breaking capacity: 1.5 KA (220V)
Size: 78 x 38 x 68 mm

Smart Control Current Protector TP-300

This is a two to three phase, 5 functions in 1 circuit breaker for industrial use. It incorporated overload, earth leakage (ground fault), phase failure, phase voltage unbalnace and surge protections. It is designed to be used with magnetic contactor in providing your motor, machinery and equipment with a total safety protection.

TP-300 Specifications
Rated voltage: 220/380V AC
50/60 Hz, 2-3 pole
Rated current: 5A - 12.5A/9A-22.5A
Overload tripping time: < 2 seconds
Unbalance voltage tripping rate:
+/- 25%
Phase failure & input voltage unbalance tripping time:
< 2 seconds
Earth leakage sensitivity: 3mA +/- 0.5mA
Earth leakage tripping time: <60 ms

Smart Control Safety Plug SP-38

This is a 4 functions in 1 plug. With earth leakage(ground fault), overload, short circuit and surge protections, it is ideal for domestic, commercial and small industrial application use.

It is designed to provide total protection to users and equipments such as power tools, home appliances, lighting fixtures, extension sockets, drum type reels, Hi Fi, computer equipments and etc. Ideal for any electrical devices as long as safety protection is your concern. Simply replace the existing plug with this Smart Control Plug and you can rest assured that you are under complete safety protection.

SP-38 Specifications
Rated voltage: 110V/220V AC
50/60 Hz, 2 pole
Rated current: 13 A
Earth leakage rated trip current: 3 mA +/-0.5mA
Earth leakage rated tripping time:
< 40 ms
Overload tripping current:
15 A +/- 1A
Overload tripping time: < 1S
Breaking capacity: 1.5 KA
Size: 79 x 48 x 50 mm

* All products are developed from our invention, patent of which has been filed in over 23 countries. Invention patent for 20 years has been granted in USA (Patent #6, 163, 444), UK (Patent #GB2303, 980A), Hong Kong Patent (#HK1002742), Taiwan (Patent #127099) and etc. following with other countries.

 

 
The above are only a few types of circuit breakers developed from our invention. Other types can be designed to suit various applications in utilizing our control circuit. Configuration and specifications can also be modified to suit any specific market requirements. Please feel free to contact us for further queries.  

Copyright © Max Leader Limited. All Rights Reserved.